TROUBLE DIAGNOSES — Electrical Components Inspection (Cont'd) — Thermo control amp / A/C relay / Thermoswitch
HA-85spec tableThermo control amp output is inverted: 12V on the meter = compressor OFF (line cold), 0V = compressor ON. Thermoswitch is the condenser-fan thermoswitch (water-temperature triggered) — only fitted to 'hot-areas' spec.
Electrical Components Inspection (Cont'd)
THERMO CONTROL AMP.
Thermo control amp — operating test
- 1Run engine, and operate A/C system.
- 2Connect the voltmeter from harness side.
- 3Check thermo control amp. operation shown in the table.
Thermo control amp — output vs evaporator outlet air temp
Decreasing to 1.5 – 2.5 (35 – 37)
Thermo amp. operationTurn OFF
TesterApprox. 12V
Increasing to 3.0 – 4.0 (37 – 39)
Thermo amp. operationTurn ON
TesterApprox. 0V
A/C RELAY
A/C relay — coil energisation test
- 1Check circuit continuity between terminals by supplying 12 volts to coil side terminal of A/C relay.
THERMOSWITCH (For hot areas)
Condenser-thermoswitch operating thresholds
Decreasing to 85 – 91 (185 – 196)
OperationTurn OFF
ContinuityDoes not exist
Increasing to 92 – 98 (198 – 208)
OperationTurn ON
ContinuityExists