TROUBLE DIAGNOSES — Preliminary Check (Cont'd) — Preliminary Check 4 (Air outlet does not change.)
HA-63spec tableNumeric percentages on the bar charts (40/50/63 for non-Europe; 36/38/50/72/79 for Europe) read directly from grid-line callouts.
Preliminary Check (Cont'd)
PRELIMINARY CHECK 4
Air outlet does not change.
NOTE
Test condition: ignition switch at ACC. Push each mode switch in turn and confirm that air comes out from the expected duct(s).
Mode switch → indicator → air outlet (expected behaviour)
VENT
Indicator illuminatedVENT icon
Air outlet — Except for EuropeVENT
Air outlet — For EuropeVENT
B/L
Indicator illuminatedB/L icon
Air outlet — Except for EuropeFOOT & VENT
Air outlet — For EuropeFOOT & VENT
FOOT
Indicator illuminatedFOOT icon
Air outlet — Except for EuropeFOOT
Air outlet — For EuropeFOOT, DEF & VENT
F/D
Indicator illuminatedF/D icon
Air outlet — Except for EuropeFOOT & DEF
Air outlet — For EuropeFOOT, DEF & VENT
DEF
Indicator illuminatedDEF icon
Air outlet — Except for EuropeDEF
Air outlet — For EuropeDEF & VENT
Air distribution ratios
NOTE
See fig2 (Except for Europe) and fig3 (For Europe) for the per-mode VENT / FOOT / DEF percentage breakdowns.
Preliminary Check 4 — air outlet does not change
1
Does air come out from each duct normally when each mode switch is pushed with ignition switch at ACC?
No
Go to Diagnostic Procedure 2.
Yes
INSPECTION END