Nissan 200SX S13 silhouetteS13

COMPRESSOR OIL — For NVR 140S (ATSUGI make) — Checking and Adjusting

HA-39prose procedure

NVR 140S (Atsugi make) compressor.

Checking and Adjusting

The oil used to lubricate the compressor is circulating with the refrigerant.

OIL CAPACITY

NVR 140S — oil capacity (Unit: mℓ / Imp fl oz)

Capacity — Total in system
Applied modelAll models
Amount mℓ (Imp fl oz)200 (7.0)
Amount of oil which can be drained
Applied modelAll models
Amount mℓ (Imp fl oz)Approx. 100 (3.5)*
Compressor (Service parts) charging amount
Applied modelAll models
Amount mℓ (Imp fl oz)200 (7.0)

OIL RETURN OPERATION

CHECKING AND ADJUSTING FOR USED COMPRESSOR

Used compressor — oil-level check / adjust

  1. 1
    After oil return operation, stop the engine and discharge refrigerant and then remove compressor from the vehicle.
  2. 2
    Drain compressor oil from compressor discharge port and measure the amount.
    Oil is sometimes hard to extract when compressor is cooled. Remove oil while compressor is warm [maintained to 40 to 50°C (104 to 122°F)].
  3. 3
    If the amount is less than 90 mℓ (3.2 Imp fl oz), some refrigerant may have leaked out. Conduct leak tests on connections of each system, and if necessary, repair or replace faulty parts.
  4. 4
    Check the purity of the oil and then adjust oil level following the procedure below.

Used-compressor adjusting procedure (a) When oil is clean

Above 90 (3.2)
Adjusting procedureOil level is right. Pour in same amount of oil as was drained out.
Below 90 (3.2)
Adjusting procedureOil level may be low. Pour in 90 mℓ (3.2 Imp fl oz) of oil.

CHECKING AND ADJUSTING FOR COMPRESSOR REPLACEMENT

Replacement-compressor oil adjustment

  1. 1
    After oil return operation, drain compressor oil from used compressor and measure the amount. (It is the same procedure as CHECKING AND ADJUSTING FOR USED COMPRESSOR.)
Oil-return operation durationAt idling, max cooling, high blower.
20 - 30minutes
Compressor oil-removal temperatureWarm-removal recommended.
40 - 50°C (104 - 122 °F)
Drain-amount threshold for leak-testIndicates refrigerant may have leaked.
< 90mℓ (3.2 Imp fl oz)

Search Manual

Search pages, specs, and procedures