A/C PERFORMANCE TEST — Performance Chart (L.H.D. model)

HA-33spec table

L.H.D.-model performance chart. R.H.D. and Europe variants on subsequent pages.

Performance Chart

TEST CONDITION

TEST READING — L.H.D. model

Recirculating-to-discharge air temperature table

Recirculating-air → discharge-air temperature (L.H.D.)

50 - 60
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)20 (68)
Discharge air temperature at center ventilator °C (°F)1.6 - 2.7 (35 - 37)
50 - 60
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)25 (77)
Discharge air temperature at center ventilator °C (°F)4.4 - 6.0 (40 - 43)
50 - 60
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)30 (86)
Discharge air temperature at center ventilator °C (°F)9.2 - 11.3 (49 - 52)
50 - 60
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)35 (95)
Discharge air temperature at center ventilator °C (°F)14.8 - 17.0 (59 - 63)
50 - 60
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)40 (104)
Discharge air temperature at center ventilator °C (°F)18.1 - 20.3 (65 - 69)
60 - 70
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)20 (68)
Discharge air temperature at center ventilator °C (°F)2.7 - 4.3 (37 - 40)
60 - 70
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)25 (77)
Discharge air temperature at center ventilator °C (°F)6.0 - 8.2 (43 - 47)
60 - 70
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)30 (86)
Discharge air temperature at center ventilator °C (°F)11.3 - 13.8 (52 - 57)
60 - 70
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)35 (95)
Discharge air temperature at center ventilator °C (°F)17.0 - 19.5 (63 - 67)
60 - 70
Inside air (Recirculating air) at blower assembly inlet — Air temperature °C (°F)40 (104)
Discharge air temperature at center ventilator °C (°F)20.3 - 22.8 (69 - 73)

Ambient air temperature-to-compressor pressure table

Ambient air → compressor pressure (L.H.D., RH 50–70 %)

50 - 70
Ambient air — Air temperature °C (°F)20 (68)
High-pressure (Discharge side) kPa (bar, kg/cm², psi)1,030 - 1,255 (10.30 - 12.55, 10.5 - 12.8, 149 - 182)
Low-pressure (Suction side) kPa (bar, kg/cm², psi)98.1 - 142.2 (0.981 - 1.422, 1.0 - 1.45, 14.2 - 20.6)
50 - 70
Ambient air — Air temperature °C (°F)25 (77)
High-pressure (Discharge side) kPa (bar, kg/cm², psi)1,196 - 1,471 (11.96 - 14.71, 12.2 - 15.0, 173 - 213)
Low-pressure (Suction side) kPa (bar, kg/cm², psi)122.6 - 171.6 (1.226 - 1.716, 1.25 - 1.75, 17.8 - 24.9)
50 - 70
Ambient air — Air temperature °C (°F)30 (86)
High-pressure (Discharge side) kPa (bar, kg/cm², psi)1,402 - 1,706 (14.02 - 17.06, 14.3 - 17.4, 203 - 247)
Low-pressure (Suction side) kPa (bar, kg/cm², psi)161.8 - 210.9 (1.618 - 2.109, 1.65 - 2.15, 23.5 - 30.6)
50 - 70
Ambient air — Air temperature °C (°F)35 (95)
High-pressure (Discharge side) kPa (bar, kg/cm², psi)1,608 - 1,971 (16.08 - 19.71, 16.4 - 20.1, 233 - 286)
Low-pressure (Suction side) kPa (bar, kg/cm², psi)205.9 - 259.9 (2.059 - 2.599, 2.1 - 2.65, 29.9 - 37.7)
50 - 70
Ambient air — Air temperature °C (°F)40 (104)
High-pressure (Discharge side) kPa (bar, kg/cm², psi)1,844 - 2,256 (18.44 - 22.56, 18.8 - 23.0, 267 - 327)
Low-pressure (Suction side) kPa (bar, kg/cm², psi)259.9 - 318.7 (2.599 - 3.187, 2.65 - 3.25, 37.7 - 46.2)
Test engine speed
1,500rpm
Time required before starting test after A/C on
> 10minutes

Search Manual