COMPRESSOR — Precautions
HA-43prose procedureIMPORTANT
Plug all openings to prevent moisture and foreign matter from entering.
Do not leave compressor on its side or upside down for more than 10 minutes.
When replacing or repairing compressor, check compressor oil level in system.
When replacing with a new compressor, drain specified oil from new compressor. Refer to COMPRESSOR OIL.
Be sure there is no oil or dirt on frictional surface of clutch disc and pulley.
When replacing compressor clutch, be careful not to scratch shaft or bend pulley.
When replacing compressor clutch assembly, do not forget BREAK-IN OPERATION.
When storing a compressor, be sure to fill it with refrigerant to prevent rust formation. Add refrigerant at the low-pressure side and purge air at the high-pressure side, while rotating shaft by hand.
When replacing parts, always use new O-rings.