TROUBLE DIAGNOSES — Main Power Supply and Ground Circuit Check (Power supply circuit + Thermo control amp.)
HA-65prose procedureConnector M9 = thermo control amp.; pin 34 = L/OR power feed; pin 13 = LG/B ground.
Main Power Supply and Ground Circuit Check
POWER SUPPLY CIRCUIT CHECK FOR A/C SYSTEM
NOTE
Check power supply circuit for air conditioning system. Refer to "POWER SUPPLY ROUTING" in EL section and A/C ELECTRICAL CIRCUIT.
THERMO CONTROL AMP. CHECK
Power-supply circuit check (with ignition switch ON)
- 1Disconnect thermo control amp. harness connector.
- 2Connect voltmeter from harness side.
- 3Measure voltage across terminal No. 34 and body ground.
Voltmeter readings — terminal 34 vs body ground
34
Voltmeter terminal (−)Body ground
VoltageApprox. 12V
Body-ground circuit check (with ignition OFF, A/C ON, fan ON)
- 1Disconnect thermo control amp. harness connector.
- 2Connect ohmmeter from harness side.
- 3Check for continuity between terminal No. 13 and body ground.
Ohmmeter readings — terminal 13 vs body ground
13
Ohmmeter terminal (−)Body ground
ContinuityYes