TROUBLE DIAGNOSES — Diagnostic Procedure 10 — Actuator Solenoid Valve Relay (L.E.D. flashing 10)
BR-57flowchartDiagnostic Procedure 10
Diagnostic Procedure 10 — solenoid valve relay
1
INSPECTION START — Remove battery negative terminal connector.
2
[A] CHECK SOLENOID VALVE RELAY RESISTANCE. Disconnect control unit connector. Check resistance between control unit connector (vehicle side) terminals ㉗ and ⑰. Resistance: 80 - 90 Ω.
N.G.
[E] Check resistance between actuator connector (actuator side) terminals ⑦ and ⑤. Resistance: 80 - 90 Ω.
O.K.
3
[B] CHECK SOLENOID VALVE RELAY MOVEMENT. Disconnect actuator connector. Check continuity between actuator connector (actuator side) terminals ⑥ and ⑨.
Yes
Replace solenoid valve relay.
No
4
[D] Check if solenoid valve relay fuse is blown.
Yes
Replace fuse.
No
5
Perform Electrical Components Inspection — ACTUATOR. (See page BR-60.)
N.G.
Replace actuator.
O.K.
6
Replace control unit.
| Specification | Value |
|---|---|
| Solenoid valve relay resistanceVehicle-side 27/17 or actuator-side 7/5. | 80 - 90Ω |
Solenoid valve relay resistanceVehicle-side 27/17 or actuator-side 7/5.
80 - 90Ω