DOOR — Power Window (Cont'd) — Amp inspection, AMP operation matrix, circuit breaker
BF-13spec tableUnverifiedPower Window (Cont'd) — POWER WINDOW AMP. INSPECTION
IMPORTANT
POWER WINDOW TIMER RELAY SYSTEM — When ignition switch ON or ST, this system is ON.
AMP. OPERATION matrix — front-driver-side door (behind door trim)
S1
ConnectionsPower source (IGN)
Manual — Stop12V
Manual — Upward12V
Manual — Downward12V
Manual — Stop12V
One-touch — Starting (upward)12V
One-touch — Keeping operation closed [?]12V
One-touch — Starting (downward) [?]12V
One-touch — Keeping operation open [?]12V
S2
ConnectionsGround
Manual — StopGround
Manual — UpwardGround
Manual — DownwardGround
Manual — StopGround
One-touch — Starting (upward)Ground
One-touch — Keeping operation closed [?]Ground
One-touch — Starting (downward) [?]Ground
One-touch — Keeping operation open [?]Ground
S3
ConnectionsFrom power window SW (ON or ST)
Manual — StopON or ST
Manual — UpwardON or ST
Manual — DownwardON or ST
Manual — StopON or ST
One-touch — Starting (upward)ON or ST
One-touch — Keeping operation closed [?]ON or ST
One-touch — Starting (downward) [?]ON or ST
One-touch — Keeping operation open [?]ON or ST
S4
ConnectionsFrom power window SW (AUTO)
Manual — StopOFF
Manual — UpwardOFF
Manual — DownwardOFF
Manual — StopOFF
One-touch — Starting (upward)ON
One-touch — Keeping operation closed [?]ON
One-touch — Starting (downward) [?]ON
One-touch — Keeping operation open [?]ON
S5
ConnectionsTo FR-driver side power-window SW (UP)
Manual — StopOFF
Manual — UpwardON
Manual — DownwardOFF
Manual — StopOFF
One-touch — Starting (upward)ON
One-touch — Keeping operation closed [?]ON
One-touch — Starting (downward) [?]OFF
One-touch — Keeping operation open [?]OFF
S6
ConnectionsTo FR-driver side power-window regulator (Upward power source)
Manual — StopApprox. 0V
Manual — UpwardApprox. over 9V
Manual — DownwardApprox. 0V
Manual — StopApprox. 0V
One-touch — Starting (upward)Approx. over 9V
One-touch — Keeping operation closed [?]Approx. over 9V
One-touch — Starting (downward) [?]Approx. 0V
One-touch — Keeping operation open [?]Approx. 0V
S7 (or S8) [?]
ConnectionsTo FR-driver side power-window regulator (Downward power source)
Manual — StopApprox. 0V
Manual — UpwardApprox. 0V
Manual — DownwardApprox. over 9V
Manual — StopApprox. 0V
One-touch — Starting (upward)Approx. 0V
One-touch — Keeping operation closed [?]Approx. 0V
One-touch — Starting (downward) [?]Approx. over 9V
One-touch — Keeping operation open [?]Approx. over 9V
Operation table for the power-window amplifier — pin-by-pin signal levels under manual operation vs one-touch (auto) operation. Signal levels: 12V / Ground / OFF / ON / Approx. over 9V / Approx. 0V. Carry out this operation check in this chart from left to right continuously.
IMPORTANT
Carry out this operation check in this chart from left to right continuously.
CIRCUIT BREAKER INSPECTION
For example, when current is 30A, the circuit is broken within 8 to 20 seconds.
NOTE
This circuit breaker is also used in the power door lock system.
| Specification | Value |
|---|---|
| Circuit breaker trip @ 30 AExample trip-time at 30 A — see graph. | 8 - 20seconds |
Circuit breaker trip @ 30 AExample trip-time at 30 A — see graph.
8 - 20seconds